AC70 VC CONTROL FREQUENCY INVERTER MANUAL
FUNCTION PARAMETER DETAILED SPECIFICATION
104
VS2 unipolar control diagram
input voltage
lower limit
VS2 input analog
input voltage
lower limit
F-57 corresponding
frequency
F-56 corresponding
frequency
frequency
VS2 bipolar control diagram
F-57 corresponding
frequency
Upper limit
input voltage
VS2 input analog
F-56 corresponding
frequency
zero point
F-56 corresponding
frequency
input voltage
Lower limit
F-57 corresponding
frequency
Frequency
Tip: When (VS2) is used as PID given or feedback channel, the function of bipolar is invalid. At this moment,
the usage of (VS2) terminal is the same with the (VS1) terminal. Namely, when (VS2) <0, frequency inverter
think the input of this port is 0.
F-50
AS terminal input
current lower limit
Range: 0.00mA-[F-51] Default: 4.20mA
F-51
AS terminal input
current upper limit
Range:[F-50]-20.00mA
Default: 19.50mA
F-52
AS terminal input current
gain
Range: 0.01-5.00
Default: 1.00
AS terminal input current lower limit
This function defines the minimum signal which received by the analog
input terminal(AS),frequency inverter will automatically filters the current signal whose value is lower than this value;
For example, if the factory setting of this value ‘4.00’,4.00-20.00mA input current is available.
AS terminal input current upper limit
This function defines the maximum signal which received by the analog
input terminal (AS), frequency inverter will automatically filters the current signal whose value is higher than this
value.
AS terminal input current gain
This function is used to amplify or reduce the (AS) terminal.