4
To move the line to see the values of some other
location, use the arrow buttons Left and Right.
RUN
READY
ALARM
I/O
Motor Current
Motor Speed
0.01A
-254rpm
Table 20: The trend curve parameters
Index
Parameter
Min
Max
Unit
Default
ID
Description
M2.2.1
View Trend curve
Go into this menu to
monitor values in a
curve form.
P2.2.2
Sampling interval
100
432000
ms
100
2368
P2.2.3
Channel 1 min
-214748
1000
-1000
2369
P2.2.4
Channel 1 max
-1000
214748
1000
2370
P2.2.5
Channel 2 min
-214748
1000
-1000
2371
P2.2.6
Channel 2 max
-1000
214748
1000
2372
P2.2.7
Autoscale
0
1
0
2373
0 = Disabled
1 = Enabled
4.1.3
BASIC
You can see the basic monitoring values and their related data in the next table.
NOTE!
Only the standard I/O board statuses are available in the Monitor menu. You can
find the statuses of all the I/O board signals as raw data in the I/O and Hardware
menu.
Do a check of the statuses of the expander I/O board in the I/O and Hardware menu when the
system asks you to do it.
MONITORING MENU
VACON · 91