Table 53: Analogue input 1 settings
Index
Parameter
Min
Max
Unit
Default
ID
Description
P3.5.2.1.1
AI1 Signal Selection
AnIN
SlotA.1
377
P3.5.2.1.2
AI1 Signal Filter
Time
0.00
300.00
s
0.1 *
378
P3.5.2.1.3
AI1 Signal Range
0
1
0 *
379
0 = 0…10V / 0…20mA
1 = 2…10V / 4…20mA
P3.5.2.1.4
AI1 Custom. Min
-160.00
160.00
%
0.00 *
380
P3.5.2.1.5
AI1 Custom. Max
-160.00
160.00
%
100.00 *
381
P3.5.2.1.6
AI1 Signal Inversion
0
1
0 *
387
0 = Normal
1 = Signal inverted
Table 54: Analogue input 2 settings
Index
Parameter
Min
Max
Unit
Default
ID
Description
P3.5.2.2.1
AI2 Signal Selection
AnIN
SlotA.2
388
See P3.5.2.1.1.
P3.5.2.2.2
AI2 Signal Filter
Time
0.00
300.00
s
0.1 *
389
See P3.5.2.1.2.
P3.5.2.2.3
AI2 Signal Range
0
1
1 *
390
See P3.5.2.1.3.
P3.5.2.2.4
AI2 Custom. Min
-160.00
160.00
%
0.00 *
391
See P3.5.2.1.4.
P3.5.2.2.5
AI2 Custom. Max
-160.00
160.00
%
100.00 *
392
See P3.5.2.1.5.
P3.5.2.2.6
AI2 Signal Inversion
0
1
0 *
398
See P3.5.2.1.6.
PARAMETERS MENU
VACON · 119
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/