P3.3.5.3 JOYSTICK SLEEP ZONE (ID 385)
Use this parameter to set the joystick sleep zone.
The AC drive stops if the joystick reference stays in the sleep zone for longer than the time
period defined in parameter P3.3.5.4 Joystick Sleep Delay.
NOTE!
The Sleep function is available only if you use the joystick to control the frequency
reference.
P3.3.5.4 JOYSTICK SLEEP DELAY (ID 386)
Use this parameter to set the joystick sleep delay.
If the joystick reference stays in the set sleep zone for longer than the sleep delay, the drive
stops and the sleep mode is activated.
NOTE!
The Joystick sleep function is disabled when the value of this parameter is set to 0.
10.4.8
JOGGING PARAMETERS
Use the Jogging function to override the normal control momentarily. You can use this
function, for example, to control the process slowly to a special status or position during
maintenance. You do not have to change the control place or other parameters.
Only when the drive is in stop state, it is possible to activate the Jogging function. You can
use 2 bi-directional frequency references. You can activate the Jogging function from the
fieldbus or by digital input signals. The Jogging function has a ramp time that is used always
when jogging is active.
The Jogging function starts the drive at the set reference. A new start command is not
necessary. The control place does not have an effect on this.
You can activate the Jogging function from the fieldbus in bypass mode with Control Word
bits 10 and 11.