Table 7: M1.32 Local/Remote
Index
Parameter
Min
Max
Unit
Default
ID
Description
1.32.1
I/O Control Refer-
ence B Selection
1
20
4
131
See P1.22
1.32.2
I/O B Control Force
DigIN
SlotA.6
425
CLOSED = Force con-
trol place to I/O B
1.32.3
I/O B Reference
Force
DigIN
SlotA.6
343
CLOSED = Used fre-
quency reference is
specified by I/O Refer-
ence B parameter
(P1.32.1)
1.32.4
Control Signal 1 B
DigIN
SlotA.4
423
1.32.5
Control Signal 2 B
DigIN
SlotA.5
424
1.32.6
Keypad Control
Force
DigIN
SlotA.1
410
1.32.7
Fieldbus Control
Force
DigIN
Slot0.1
411
1.32.8
External Fault
(Close)
DigIN
SlotA.3
405
OPEN = OK
CLOSED = External
fault
1.32.9
Fault Reset (Close)
DigIN
Slot0.1
414
Resets all active faults
when CLOSED
1.4.3
MULTI-STEP SPEED APPLICATION
You can use the Multi-step speed application with processes where more than 1 fixed
frequency reference is necessary (for example test benches).
It is possible to use 1 + 7 frequency references: 1 basic reference (AI1 or AI2) and 7 preset
references.
Make a selection of the preset frequency references with digital signals DI4, DI5 and DI6. If
none of these inputs are active, the frequency reference is removed from the analogue input
(AI1 or AI2). Give the start/stop commands from the I/O terminal (DI1 and DI2).
It is possible to configure all the drive outputs freely in all the applications. There are 1
analogue output (Output Frequency) and 3 relay outputs (Run, Fault, Ready) available on the
basic I/O board.