8.1.2
MAINS VOLTAGE 525-690 V
Table 25: The power ratings of Vacon
®
100 in mains voltage 525-690 V, 50-60 Hz, 3~
Frame
Drive
type
Loadability
Motor shaft power
Low
High
Max
curre
nt I
s
2s
600 V mains
690 V mains
Contin
uous
curre
nt
I
Lout
[A]
Input
curre
nt I
Lin
[A]
10%
over-
load
curre
nt [A]
Contin
uous
curre
nt
I
Hout
[A]
Input
curre
nt I
Hin
[A]
50%
over-
load
curre
nt [A]
10%
over-
load
40
◦
C
[hp]
50%
over-
load
40
◦
C
[hp]
10%
over-
load
40
◦
C
[kW]
50%
over-
load
40
◦
C
[kW]
MR8
0080
80.0
90.0
88.0
62.0
72.0
93.0
124.0
75.0
60.0
75.0
55.0
0100
100.0
106.0
110.0
80.0
89.0
120.0
160.0
100.0
75.0
90.0
75.0
0125
125.0
127.0
137.5
100.0
104.0
150.0
200.0
125.0
100.0
110.0
90.0
MR9
0144
144.0
156.0
158.4
125.0
140.0
187.5
250.0
150.0
125.0
132.0
110.0
0170
170.0
179.0
187.0
144.0
155.0
216.0
288.0
-
-
160.0
132.0
0208
208.0
212.0
228.8
170.0
177.0
255.0
340.0
200.0
150.0
200.0
160.0
MR10
0261
261.0
272.0
287.1
208.0
223.0
312.0
416.0
250.0
200.0
250.0
200.0
0325
325.0
330.0
357.5
261.0
269.0
391.5
522.0
300.0
250.0
315.0
250.0
0385
385.0
386.0
423.5
325.0
327.0
487.5
650.0
400.0
300.0
355.0
315.0
0416* 416.0
415.0
457.6
385.0
382.0
577.5
770.0
450.0
300.0
400.0
355.0
MR12
0460
460.0
477.0
506.0
416.0
433.0
624.0
832.0
450.0
400.0
450.0
400.0
0520
520.0
532.0
572.0
460.0
472.0
690.0
920.0
500.0
450.0
500.0
450.0
0590
590.0
597.0
649.0
520.0
527.0
780.0 1040.0 600.0
500.0
560.0
500.0
0650
650.0
653.0
715.0
590.0
591.0
885.0 1180.0 650.0
600.0
630.0
560.0
0750* 750.0
747.0
825.0
650.0
646.0
975.0 1300.0 700.0
650.0
710.0
630.0
0820* 820.0
813.0
902.0
650.0
739.0
975.0 1300.0 800.0
650.0
800.0
630.0
* = The maximum ambient temperature is 35°C with the du/dt filter option. These currents
are not available when you have the options back channel cooling and du/dt filter (+CHCB
and +PODU).
8.1.3
BRAKE RESISTOR RATINGS
Make sure that the resistance is higher than the set minimum resistance. The power
handling capacity must be sufficient for the application.
TECHNICAL DATA, VACON® 100
VACON · 95
24-HOUR S358 (0)201 212 575 · EMAIL: [email protected]
8