14-4
PROGRAM FUNCTION KEY
Create Programs---->1-3
Voice Operations---->4
Change Setup-------->5
You have correctly entered the
password and are in Programming
Mode. Select the function you want by
pressing the correct key.
Key the number that
corresponds to what you want
to do.
PROGRAM NOT SET
HIT ANY KEY_
You have requested to collect data in a
program that has not been defined, or
you are trying to transmit a program
that has not been defined.
HIT ANY KEY. Enter the
correct program number or go
to Programming Mode to
create a new program.
PROGRAM NO.?
KEY [0-3]?_
You are in Data Collection mode and
need to select a program to use.
Key 0, 1,2 or 3.
PROGRAM RECEIVE
KEY [Y/N]?_
Do you want to receive a program from
another TriCoder or host computer?
Press YES to go to Receiving
Menu. Press NO to go to the
Mode Menu.
PROGRAM TRANSMIT
KEY [Y/N]?_
Do you want to transmit a program to
another TriCoder or a host computer?
Press YES to go to Transmit
Menu.Press NO to go to Mode
Menu.
RECEIVE PROGRAM KEY
Programs[1-3]?-->1-3
Clone TriCoder?->0
You have answered YES to program
receive mode. Choose the program to
receive into or choose to clone.
Press the Program # or 0 to
Clone.
RECEIVING PROG.
PLEASE WAIT>
A program is being received by the
TriCoder.
Wait for next message.
RECEIVING INTERRUPTED
Key Pressed In Error
Restart Transmission
Hit any Key_
A key was pressed on the TriCoder
after program transfer had started,
aborting the transmission. TriCoder
contains invalid program information.
Hit any Key. Restart
transmission. Do not press
any keys on TriCoder once
transmission has begun.
RTC ERROR
Call 831-458-9938
This error should not occur and
indicates a firmware problem. Try to
record what led to this error.
Cycle Power to clear, Call for
support.
SEARCH PATTERN
_
The SEARCH key was pressed.
Enter data to search for or
press ENTER key to exit.
SENDING PROGRAM
PLEASE WAIT_
You are transmitting a program from
the TriCoder. Wait for completion.
Wait for next message.
SRAM SIZE ERROR
You are trying to clone from a higher
memory capacity TriCoder (i.e. 512K)
to a lower memory capacity TriCoder
(i.e. 256K)
You cannot do this. You can
clone from lower to higher but
not higher to lower. Use a
lower capacity TriCoder as
your master.
SRAM WRITE ERROR
CYCLE POWER_
A serious error was detected. If
persistent, call for RMA.
Turn TriCoder OFF/ON. Call
for support if error continues
to occur.
Start Host Program
Then Hit Any Key
TriCoder is ready to receive from the
host via USB, (i.e. Table, Program, or
Firmware Download)
Start the host computer
program, i.e. TriCoder Utilities,
then Hit Any key.
Start Host USB
Firmware Download
Program First and
Then Hit Any Key.
Firmware download has been
requested. USB enumeration has been
completed. Now TriCoder is requesting
the user to start PC TriCoder Firmware
Downloader.
Start the Windows program,
TriCoder Firmware
Downloader. Available on
TriCoder Utilities CD ROM, or
on www.barcodehq.com.
TABLE DOWNLOAD?
KEY [YES/NO]?_
A table has been defined in the
memory partitions - you can now
download a table into the TriCoder.
Press YES to continue with
table download.
Press NO to return to Mode
Menu.
TABLE FORMAT ERR
PRESS ANY KEY_
The table header is in an invalid format
or EOF Ctrl Z (ASCII 26) is missing.
Check table file for format
errors. Try again.
TABLE NOT AVAILABLE
HIT ANY KEY_
The host program has told the
TriCoder it has no table to download.
Try again later.
TABLE NOT DEFINED
HIT ANY KEY_
You are trying to download a table to a
table number that is not defined in the
Partitions.
Go to Setup and define the
table in the Partitions
parameter.
TABLE NOT FOUND
HIT ANY KEY_
A table referenced in a data collection
program does not exist.
Download table or correct
program to reference correct
table.
TABLE NUMBER
KEY [1-3]?_
You have requested to download a
table. Now choose which table number
you want to download to.
Choose a defined table
number to download to.