![TriCoder Portable Bar Code Reader Owner'S Manual Download Page 184](http://html.mh-extra.com/html/tricoder/portable-bar-code-reader/portable-bar-code-reader_owners-manual_1162123184.webp)
D-2
Mod 8 RJ45
Function
DB25 Male
1 Frame
Ground 1
2 Transmit
Data 2
3 Receive
Data 3
4 Signal
Ground 7
5
6
7 20
8 4
Table I-3. F34A Modem Cable
Pins 5 and 6 are not connected at the DB25 end. Pins 20 and 4 are tied together.
F46B 9 Pin Modem Cable
This cable is for use in Modem communications. It is a DB9 male to 8 pin
modular cable.
Mod 8 RJ45
Function
DB 9 Male
1
Shell
(chassis ground)
Shell
2 Transmit
Data 3
3 Receive
Data 2
4 Signal
Ground 5
5
6
7 4
8 7
Table I-4. F46B 9 Pin Modem Cable
Pins 5 and 6 are not connected at the DB9 end. Pins 4 and 7 are tied together.
422 Cable pin-outs
RS-422 allows multiple numbers of TriCoders to be "multi-dropped" off a
single 422 serial port. Maximum distance for RS-422 is 4000 feet. Using
the following pin-outs, you can make your own 422 "multi-drop" cables by:
1. Tying
T+
on the TriCoder end to the
R+
on the continuous 422 line.
2. Tying
T-
on the TriCoder end to the
R-
on the continuous 422 line.
Function
Mod 8
Transmit Data + (
T+
)
2
Transmit Data - (
T-
)
3
Ground
4
Receive Data + (
R+
)
5
Receive Data - (
R-
)
6
Table I-7. RS-422 Multi-drop cable