![TriCoder Portable Bar Code Reader Owner'S Manual Download Page 185](http://html.mh-extra.com/html/tricoder/portable-bar-code-reader/portable-bar-code-reader_owners-manual_1162123185.webp)
D-3
You must have
T+/T-
in one twisted pair and
R+/R-
in the other.
We suggest using our F44 422 "Y" Cable instead. One end of this cable
goes into the TriCoder, the other 2 ends have female modular 8 pin
connectors. The only cables you provide are cables with male modular 8
pin connectors on each end to connect between TriCoders and a cable
coming from the 422 serial port with a male modular 8 pin connector to
connect to the first TriCoder. At the end of the string of TriCoders, tie pins
2&3 and 5&6 together with 120 ohm resistors or order our 422 terminator
plug. We recommend using Belden 1227AI (or Category 5 cable if you
don’t want to buy new wire) for all of the 422 cabling above.
Beside the standard cable pin-outs provided above, there are several other
cable pin-outs which may prove useful to users.
F38 Data Cloning Cable
The pin-outs for the F38 TriCoder Data cloning cable (Male RJ45 on both
ends) are:
Wedge/RS-232
RS-422
RJ45 male RJ45 male
RJ45 male RJ45 male
1
1
2
5
2 3
3 6
3 2
4 4
4 4
5 2
6 6
6 3
Table I-9. F38 Data Cloning Cable
Laser and CCD
The laser and CCD TTL pin-outs are:
Pin
Function
1 5
volts
2 Data
3 Phase
4 LED
5 Trigger
6 Enable
7 Shield(drain)
8 Ground
Table I-11. Laser and CCD Pin-outs