Program 11-IP : Date and Time Setting
11-IP Date/Time
08 27 06 18 16 4
IP =Item pointer (01-06)
Value for each Item
IP
Value
Item Description
11-01
01-12
Month......................
11-02
01-31
Day........................
11-03
00-99
Year.......................
11-04
00-23
Hour.......................
11-05
00-59
Minute.....................
11-06
1-7
Week day (Monday = 1, Tuesday = 2)..
General:
This program set up the system’s Date & Time.
Description:
The Date & Time will be held during power failure of G1E plus. There is no need to reset the Date & Time after power
is restored.
Program 12-nn : System Alarm Clock
12-nn Alarm
hh mm dd
nn = Alarm schedule (01-10)
Setting Time
Location
Program
Program Data
Pointer
Data
Description
-----------
----------
---------------------------
hh
00-23
Hour.
mm
00-59
Minute.
dd
00-99
Duration.
General:
This program permits the assignment of 10 time schedules for alarm clock purposes.
Description:
When the assigned time is reached, Background music will be broadcast over all idle Key telephones.
The time duration for alarm clock music is programmable (00 to 99 minutes.).
Lifting the handset and returning it to the cradle or pressing the SPK key will cause the background music to cease on
that telephone only.
Summary of Contents for G1E Plus
Page 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Page 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Page 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 113: ......
Page 126: ...Program 93 Not Used in North America ...
Page 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...