IP \ Value
0
1
50-stn-02
Disable
Enable
03. ISDN Incoming Call Display Type-Digital Phone:
This parameter selects what will be displayed on the screen of an LCD phone when an incoming call is received, either
the CLI number or the ISDN In dial number. This will also select what will be displayed on the SMDR output for
incoming calls. This setting also allows the naming of In dials or CLI numbers using System Speed Dial Name /
numbers. If this setting is a 1 then when an incoming call with CLI or an In dial number rings the G1E will search the
System Speed dials and if this number is entered then the name associated with it will be displayed on the screen.
Because ISDN CLI currently omits the 0 on CLI It will be necessary to set Mode 84 – Home Area code to correct the
settings before searching. The In dial number is entered as the standard 7/8 digit number without area code. The SLT
phone on the G1E will only display the calling number not the name.
IP \ Value
0
1
50-stn-03
CLI / Name
ISDN In dial Number / Name
04. CTI-Extension Status Report
Enabling this parameter will output the extensions status report for CTI applications. This parameter will need to be
enabled before CTI will work with this station.
IP \ Value
0
1
50-stn-04
Disable
Enable
05. VMS Leading Digits For Intercom Calls
Enabling (disabling) this parameter allows the system to send (not send) the leading digit information of the extension
when making an intercom call to the voice mail. This allows the operator to transfer someone’s call directly to the
selected Voice mail box.
IP \ Value
0
1
50-stn-05
Enable
Disable
Related System Programming Mode:
05-12-05
06. ACP Door Unlock Relay
This parameter can select MBU’s relay or ACP relay as Door unlock relay. If the MBU’s relay is enabled then both the
ACP relay and the MBU’s relay will operate for that door phone. This will allow a more secure door opening method
when multiple ACP and Door unlocking are used.
IP
Value
Value Description
50-stn-06
0
Use ACP relay
50-stn-06
1
Use G1E-MBU’s (Mode 06-00 needs to be assign to ‘2’ ) and ACP relay
Related System Programming Mode:
05-12-04, 06
07. ACP Door Open Control
This parameter sets what action is required to open the door lock from an ACP / RFID phone.
IP
Value
Value Description
50-stn-07
0
RF Proximity card OR Password
50-stn-07
1
RF Proximity Card AND Password
Summary of Contents for G1E Plus
Page 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Page 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Page 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 113: ......
Page 126: ...Program 93 Not Used in North America ...
Page 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...