Program 06-IP : Relay Assignment
06-St-01 Relay
00
St= Station Number
Value for each Item
St
Item Value
Relay Description
000
00-06, 10, 11-18
Relay of Motherboard (Optional)
xxx
00-06, 10, 11-18
Relay of ACP (extension: xxx)
Description:
Relays on the Motherboard and ACP are dry-contact type relays. The relay provides no power, only a switching
function.
The maximum limit for the voltage and current for the relay contacts is 24Vdc or 90Vac at 1 A.
They are only designed for low voltage control circuits. All Relays are Normally Open contacts and will close on
activation of the function for which they have been programmed.
When the St is 000, it means the relay on the motherboard. When the St is a valid station number, it is the relay on the
ACP corresponding to that station number..
Assign the required Relays to one of the following functions.
Item Value
Function
00
No Operation
01
Music On Hold
02
Reserved for future use
03
Reserved for future use
04
Trunk loud bell
05
Station loud bell
06
System Alarm
10
All Paging [#0]
11
External zone page Group - 1 [#31]
12
External zone page Group - 2 [#32]
13
External zone page Group - 3 [#33]
14
External zone page Group - 4 [#34]
15
External zone page Group - 5 [#35]
16
External zone page Group - 6 [#36]
17
External zone page Group - 7 [#37]
18
External zone page Group - 8 [#38]
Summary of Contents for G1E Plus
Page 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Page 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Page 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 113: ......
Page 126: ...Program 93 Not Used in North America ...
Page 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...