Program 05-01-IP : System Timing Parameters – 01
05-01-IP SYS PAR
1 1 1 1 4 2 2 1
IP=Item Pointer (01-08)
Value for each Item
IP
Value
Default
Item Description
01
0-9
1= 60 sec.
Hold Recall Time
02
0-9
1= 60 sec.
Exclusive Hold Recall Time
03
0-9
1= 60 sec.
Hold Recall Timeout
04
0-9
1= 2 sec.
DISA & ECF Access Delay Time - Day
05
0-9
4= 8 sec.
Busy Remind Cycle Time
06
0-9
2= 800 ms
Pause Time
07
0-9
2= 83 ms
DTMF Generation Time
08
0-9
1= 20 sec.
Call Forward No Answer Transfer Time
01. Hold Recall Time
This parameter sets the duration from the time the line is put on Hold until the held call recalls the station.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-01-01
30
60
90
120
150
180
210
240
253 None sec.
02. Exclusive Hold Recall Time
This parameter sets the time duration from the line is put on Exclusive Hold to the held call recalls the station.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-01-02
30
60
90
120
150
180
210
240
253 None sec.
03. Hold Recall Timeout
This parameter sets the timer between a held call recalling to a holding or transferring station (i.e., 05-01-01 or 05-01-
02 expires) and then recalling to the console if unanswered.
IP \ Value
0
1
2
3
4
5
6
7
8
9
Unit
05-01-03
30
60
90
120
150
180
210
240
253 None sec.
Summary of Contents for G1E Plus
Page 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Page 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Page 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 113: ......
Page 126: ...Program 93 Not Used in North America ...
Page 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...