I
Program 39-IP : Sensor Assignments
39-STN-IP Sensor
FN S
STN = Station No. ( 00 / 000 / 0000) 2/3/4 digits
sensor on the motherboard
39-STN-IP Sensor
FN S
STN = ACP station number
Sensor on the ACP
IP
Value
Item Description
39-STN-01
00-18
Function No.
39-STN-02
0-2
Sensor Type
Description:
The G1E-MBU and each ACP provides 1 Sensor.
FN= Function No.
S=Sensor Type
Each Sensor can be assigned to one of the following 18 functions.
FN
Function
00
No Operation
01
Fire Alarm
02
Break Alarm
03
Door Phone 1
04
Reserved for future use
05
Security feature
06-18
Reserved for future use
The valid sensor types for sensor on the motherboard:
S
Item Description
0
Disable Sensor function
1
Normally Open for night
2
Normally Closed for night
3
Normally Open day
4
Normally Closed Day
5
Normally open Day/Night
6
Normally Closed Day/night
The valid sensor types for sensor on the ACP:
Value
Item Description
0
Disable Sensor function
1
Normally Open
2
Normally Closed
Summary of Contents for G1E Plus
Page 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Page 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Page 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 113: ......
Page 126: ...Program 93 Not Used in North America ...
Page 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...