Introduction
The manual contains all the parameters that are programmable inside the G1E+ Hybrid IP Telephone System.
New Systems
We recommend that all new systems have the system memory reset before system programming takes place. This
ensures that any extraneous information that may be present in system memory is erased and that the system
database will not be subject to existing corrupt data.
To reset the database in G1E+, from a LCD display phone, enter programming by pressing [PRG], [2], Enter Password
if programmed (new systems will not have a system password). Press [SAVE] key. The LCD display will show as
follows:
Then enter [2] [5] and press [SAVE]. You will be in Program Mode 25-01. The display will show:
Enter [2] to reset all data. The phone will beep and return to the previous screen.
You may begin database entry at this point or exit system programming by pressing [SPK] key or by lifting and
replacing the handset.
A station can access a CO trunk and talk on a phone while entering system programming mode.
This allows a
technician to guide a customer into program mode and make minor changes by programming the system data during
the conversation.
Basic Programming Commands
Note:
Keys listed between [ ] indicate the physical location on a telephone set. Keys listed between { }
indicate key functions when in programming.
These commands are active while in the system programming mode
[DSS 36]
{PRG}: Moves to the Top Level Programming Mode Display (does not save information
entered into any field unless [SAVE] is pressed first).
[DSS 35]
{SAVE}: Commits the data that is shown on the LCD display into the system database.
[DSS 1]
{PREV}: Moves to the previous section of any multiple part form.
[DSS 2]
{NEXT}: Moves to the next section in any multiple part form.
[DSS 3]
{LEFT}: Moves the programming cursor to the left position.
[DSS 4]
{RIGHT}: Moves the programming cursor to the right position.
[DSS 34]
{DND/CN}: Enters a Wild Card (don't care) into Account Codes or Toll control entries. LCD
will display d (lower case letter "d") to indicate don't care entry.
[HOLD]
{PAUSE}: Inserts a Pause when programming a Speed Dial Entry or for Voice Mail
Programming. LCD will display p (lower case "p") to indicate a Pause entry.
PROGRAM MODE: __
(01 – 95)
25- Reset Data
0-9 Default
Summary of Contents for G1E Plus
Page 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Page 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Page 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 113: ......
Page 126: ...Program 93 Not Used in North America ...
Page 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...