hear the oscillation noise on the speaker. Pressing [MIC] key twice to mute the handset’s microphone will eliminate
this noise.
Definition of Parameter:
IP \ Value
0
1
48-stn-03
Enable Group Listen Disable Group Listen
04. Reserved
05. Reserved
06. Reserved
07. Reserved
08. Reserved
Program 50-stn-IP : Station Class of Service – 6
50-stn-IP STCOS
0 0 0 0 0 0 0 0
Stn=Station No. (2-4 digits), IP =
Item Pointer (01-08)
Value for each Item
IP
Value
Default
Item Description
01
0-1
0=Disable
ACP Warning Signals
02
0-1
0=Enabled
Call Forward Indication
03
0-1
0=CLI
ISDN Incoming Call Display type-Digital phone
04
0-1
0=Disable
CTI-Extension Status Report
05
0-1
0=Enable
VMS Leading Digits for Intercom Calls
06
0-1
0=ACP Relay
ACP Door Unlock Relay
07
0-1
0=Card or P/Word
ACP Door Open Control
08
0-1
0=Door Phone / Disable
ACP Phone Operation / Hotel Alarm Type
General:
This program permits each station to be assigned to a different Class of Service.
Description:
01. ACP Warning Signals
This Parameter enables the warning signals for the ACP/RFID unit. The warning signals are ACP’s Case Break-in
Alarm and Disconnect Alarm.
IP \ Value
0
1
50-stn-01
Disable
Enable
02. Call Forward Indication:
This feature will disable the flashing SPK key on a handset that has enabled Call Forward.
Summary of Contents for G1E Plus
Page 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Page 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Page 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 113: ......
Page 126: ...Program 93 Not Used in North America ...
Page 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...