04. Polarity Reversal
This parameter is to enable the Polarity Reversal detection feature for incoming caller hang up detection in Australia
and some European countries. See Mode 14-01-08 for SMDR setting. Telecom provider needs to enable its polarity
reversal feature at the central office. When this reversal is enabled the system will hang up the CO line when the
incoming caller hangs up and the CO sends a Polarity Reversal signal to the system.
Note: 2-9 =Delay for 1-8 Seconds after accessing the line and then detect Polarity Reverse Signal
05. Operator Code
This parameter is to set whether to dial "0" or "9" for calling the operator or accessing a CO. line.
IP \ Value
0
1
05-06-05 Dial "0" for operator, "9" for C.O. line.
Dial "9" for operator, "0" for C.O. line.
06. Unsupervised Conference & ECF Time Setting
This timer defines the allows time duration on Unsupervised Conference or ECF (External Call Forward) calls. The
system will send a warning tone prior to disconnecting the call. If either party sends a DTMF digit (0-9) to the system
the timer will reset and allow the call to continue for this time setting. If reversal supervision is used, system will
release the line when reversal signal is detected.
07. Hold Feature for SLT
This parameter is to set whether Single Line Telephones use [FLASH] or [FLASH, 7] to place a call on Hold.
IP \ Value
0
1
05-06-07
Normal
Use [FLASH] to place a call on Hold.
Alternate
Use [FLASH, 7] to place a call on Hold.
08. Station Hunting Group - Ring Method:
This parameter sets the ring method used in the station hunting groups. Pilot numbers for hunt groups are set in
Program 67, Day/Night ring stations are set in Program 68 & 69, Individual Hunt Group Ring type can be set in
Program 67-gp-02 and will over ride the system wide setting made here.
IP \ Value
0
1
2
05-06-08
Common
Linear
Circular
IP \ Value
0
1
2 to 9
05-06-04
Disable
Enable
Enable after 1 to 8 seconds delay
IP \ Value
0
1
2
3
4~9
Unit
05-06-06
No Limit
1
2
3
4
Min.
Summary of Contents for G1E Plus
Page 1: ...G1E Hybrid IP Telephone System Programming Manual Rev 2 2d ...
Page 15: ...DK6 Key Telephone Key Layout 36 Button DK6 Key Telephone Key Layout 18 Button ...
Page 48: ...03 Reserved 04 Reserved 05 Reserved 06 Reserved 07 Reserved 08 Reserved ...
Page 113: ......
Page 126: ...Program 93 Not Used in North America ...
Page 131: ...35 trk 01 Trunk Type PABX CO 35 trk 02 Trunk Signalling Type dial pulse DTMF ...