Voice Mail Configuration
Parameters
Strata CIX Voice Mail Programming 01/07
3-39
sys_max_guest_box
Last mailbox number that can be used when creating a Guest Mailbox.
When used with the
sys_min_guest_box
parameter, they limit the number of
Guest Mailboxes that can be created.
Example:
If this value is 90200, then the last Guest Mailbox that can be
created is Mailbox 90200.
Possible values: valid mailbox number larger than the
sys_min_guest_box
parameter setting
Default: 90200
sys_max_prompt
Number of times a prompt should repeat until deciding to hang up.
Possible values: 1~9
Default: 3
sys_max_sec_code_len
Controls the maximum length security code that voice mail accepts as a new
security code when a user attempts to change it from a telephone.
Note
Value must be greater than or equal to the minimum length security
code (i.e., sys_min_sec_code_len).
Possible values: 1~16
Default: 16
sys_max_silence
Specifies maximum number of milliseconds in silence before recording is
terminated.
Default: 5000 ms
sys_maximum_box_length
Maximum number of digits voice mail expects in the case that the maximum
number of digits voice mail expects for the beginning digit of that mailbox
number is not defined.
Default: 5
sys_min_guest_box
Starting mailbox number that may be used when creating a Guest Mailbox.
When used with the
sys_max_guest_box
parameter, they limit the number of
Guest Mailboxes that can be created.
Examples: If this value is 90000, then the first Guest Mailbox that is created
is Mailbox 90000. The second guest has Mailbox 90001, etc.
Possible values: valid mailbox number smaller than
sys_max_guest_box
parameter setting
Default: 90000
sys_min_sec_code_len
Controls the minimum length security code that voice mail accepts as a new
security code when a suer attempts to change it from a telephone.
Note
Value must be less than or equal to the maximum length security code
(i.e., sys_max_sec_code_len).
Possible values: 1~16
Default: 3
sys_minimum_message_length
Minimum message length in milliseconds for the system to be able to
recognize the message.
Default: 1000 ms
sys_minimum_record_length
Minimum record length in milliseconds.
Default: 100 ms
Table 3-12
Parameter Definitions
(continued)
Parameter
Description
Summary of Contents for STRATA CIX
Page 1: ...Strata CIX Programming Manual Volume 2 Stratagy ES Voice Mail Application Release 5 ...
Page 16: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 138: ...This page is intentionally left blank ...
Page 140: ...This page is intentionally left blank ...
Page 170: ...This page is intentionally left blank ...
Page 176: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 230: ...This page is intentionally left blank ...
Page 238: ...This page is intentionally left blank ...
Page 247: ...THIS IS THE LAST PAGE OF THE DOCUMENT ...
Page 248: ......