TMS320C67x Extensions to the Control Register File
2-18
2.7.3
Floating-Point Multiplier Configuration Register (FMCR)
The floating-point multiplier configuration register (FMCR) contains fields that
specify underflow or overflow, the rounding mode, NaNs, denormalized num-
bers, and inexact results for instructions that use the .M functional units. FMCR
has a set of fields specific to each of the .M units, .M1 and .M2. Figure 2–9
shows the layout of FMCR. The functions of the fields in the FMCR are shown
in Table 2–10.
Figure 2–9. Floating-Point Multiplier Configuration Register (FMCR)
31
RMode
INEX OVER
INVAL
24
23
22
21
20
19
18
17
16
NAN1
R, +0
R, W, +0
DEN2
INFO
UNDER
Reserved
27 26 25
NAN2
DEN1
Fields used by .M2
15
RMode
INEX OVER
INVAL
8
7
6
5
4
3
2
1
0
NAN1
R, +0
R, W, +0
DEN2
INFO
UNDER
Reserved
11 10 9
NAN2
DEN1
Fields used by .M1
Legend: R
Readable by the MVC instruction
W
Writeable by the MVC instruction
+0
Value is zero after reset