SADD
Integer Addition With Saturation to Result Size
3-102
Pipeline
Stage
E1
Read
src1, src2
Written
dst
Unit in use
.L
Instruction Type
Single-cycle
Delay Slots
0
Example 1
SADD .L1
A1,A2,A3
Before instruction
1 cycle after instruction
2 cycles after instruction
A1
5A2E 51A3h
1512984995
A1
5A2E 51A3h
A1
5A2E 51A3h
A2
012A 3FA2h
19546018
A2
012A 3FA2h
A2
012A 3FA2h
A3
XXXX XXXXh
A3
5B58 9145h
1532531013
A3
5B58 9145h
CSR
0001 0100h
CSR
0001 0100h
CSR
0001 0100h
Not saturated
Example 2
SADD .L1
A1,A2,A3
Before instruction
1 cycle after instruction
2 cycles after instruction
A1
4367 71F2h
1130852850
A1
4367 71F2h
A1
4367 71F2h
A2
5A2E 51A3h
1512984995
A2
5A2E 51A3h
A2
5A2E 51A3h
A3
XXXX XXXXh
A3
7FFF FFFFh
2147483647
A3
7FFF FFFFh
CSR
0001 0100h
CSR
0001 0100h
CSR
0001 0300h
Saturated