20 : USSD/SS Transaction terminated by user
32 : TA currently unable to process command
34 : user has denied SIM/USIM call setup request
35 : user cleared down SIM/USIM call before
connection or network release
<data>
string
-
data entered by user, see Additional
info section
Additional info:
<data> parameter is used according to <cmdType>, and when
<userAction>=0:
<cmdType>=34 (GET INKEY)
<data> contains the key pressed by the user. The character set is
selected by +CSCS command.
If the ongoing proactive command requires to the user a binary
choice (yes/no), the valid content of <data> is:
- "Y" or "y" (positive answer) and "N" or "n" (negative answer) for
"IRA", "8859-1", "PCCP437" character sets
- "0079" or "0059" (positive answer) and "006E" or "004E"
(negative answer) for UCS2 alphabet
The ongoing proactive command to require a binary choice sets bit 2
of the <cmdDetails> parameter to 1, see #STGI command.
<cmdType>=35 (GET INPUT).
<data> contains the string of characters entered by the user.