3.2.2.35.
AT+CCWE - Call Meter Maximum Event
This command is used to enable/disable sending of an unsolicited result code +CCWV.
3GPP TS 27.007
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Specific profile
No
-
2
AT+CCWE=<mode>
Set command is used to enable/disable sending of an unsolicited result
code +CCWV shortly before the ACM (Accumulated Call Meter) maximum
value is reached. The warning is issued approximately when 30 seconds
call time remains. It is also issued when starting a call if less than 30
seconds call time remains.
Parameter:
Name
Type
Default
Description
<mode> integer
0
Current enable mode of +CCWE URC
Values:
0 : Disable the call meter warning event
1 : Enable the call meter warning event
The set command will respond with an error if the Accumulated
Call Meter service is not active in SIM.
<mode> is saved in NVM.
AT+CCWE?