LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 1114 of 1904
2022-03-04
Not Subject to NDA
•
AT#TEMPCFG= -273,-33,3,-35,-28,2,-30,80,0,78,90,3,88,105,3
OK
Rules 1 and 2 are respected.
zone
thr_clr thr
action_in
Extreme low
zone
-273
-33
3: emergency call
only
Operate low
zone
-35
-28
2: TX back off
Operate
normal zone
-30
80
0: no mitigation
Operate up
zone
78
90
3: emergency call
only
Extreme up
zone
88
105
3: emergency call
only
•
AT#TEMPCFG=-273,-33,3,-35,-28,2,-30,80,0,79,90,3,88,105,3
+CME ERROR: operation not supported
Rule 1 is not respected - Hysteresis is lesser than 2 deg :
(thr of Operate normal zone) - (thr_clr of Operate up zone) = 1 < 2
zone
thr_clr thr
action_in
Extreme low
zone
-273
-33
3: emergency call
only
Operate low
zone
-35
-28
2: TX back off
Operate normal
zone
-30
80
0: no mitigation
Operate up
zone
79
90
3: emergency call
only
Extreme up
zone
88
105
3: emergency call
only
•
AT#TEMPCFG=-273,-33,3,-35,-28,2,-30,80,0,78,90,3,81,105,3
+CME ERROR: operation not supported