#FOTAURC command examples:
•
LwM2M:
After writing resource /5/0/1 with a proper URI with a valid delta
package link:
#OTAEV: "FOTA REQUEST INIT"
#OTAEV: "DOWNLOAD STARTED"
#OTAEV: "DOWNLOAD COMPLETED"
#OTAEV: "INTEGRITY CHECK PASS"
#LWM2MINFO: "GEN","FOTA REBOOT"
#OTAEV: Module Upgraded To New Fw
After writing resource /5/0/1 with a proper URI with an invalid delta
package link:
#OTAEV: "FOTA REQUEST INIT"
#OTAEV: "DOWNLOAD STARTED"
#OTAEV: "DOWNLOAD COMPLETED"
#OTAEV: "INTEGRITY CHECK FAIL"
After writing resource /5/0/1 with a proper URI, with a download
failure:
#OTAEV: "FOTA REQUEST INIT"
#OTAEV: "DOWNLOAD STARTED"
#OTAEV: "DOWNLOAD FAILED"
•
FA1:
After sending an FA1 message with a valid delta package link:
#OTAEV: "FOTA REQUEST INIT"
#OTAEV: "DOWNLOAD STARTED"
#OTAEV: "DOWNLOAD COMPLETED"
#OTAEV: "INTEGRITY CHECK PASS"
#OTAEV: "FOTA REBOOT"
#OTAEV: Module Upgraded To New Fw
Summary of Contents for LE910C series