3.19.11.
AT#EMAILPDPCFG - Configure Email PDP Cid
This command gets configure email PDP cid
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#EMAILPDPCFG=<cid>
This command sets the cid that used for email PDP Context
Parameter:
Name
Type
Default
Description
<cid> integer
-
Numeric parameter indicating the PDP
Context Identifier Range: (1-max).
Default: 1( in VZW products default is 3)
The value of max is returned by the Test
command
AT#EMAILPDPCFG?
Read command returns the current used cid in the format:
AT#EMAILPDPCFG?
#EMAILPDPCFG: 1
OK
AT#EMAILPDPCFG=?
Test command reports the supported range of values for parameter <cid>.