3.7.8.
AT#CLKSRC - Set Time Clock Source
This command selects the source time clock.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#CLKSRC=<src>
Set command selects the source time clock for the system between NITZ,
GNSS or a combination between.
Parameter:
Name
Type
Default
Description
<src>
integer
0
sets the clock
source
Values:
0 : NITZ time only
1 : GNSS time only
2 : GNSS time priority
3 : NITZ time priority
4 : DISABLE. With this value, clock source shall not be
update not by NITZ nor by GNSS. The only possibility to
set it is by manual setting.
AT#CLKSRC?
Read command reports the current clock source configuration.
#CLKSRC: <src>,<curr>
<src> - see description above.