
Teledyne
LeCroy
Protocol
Analyzer
30
SierraNet
M408
User
Manual
1.6 Protocol
Analyzer
To
use
the
software
for
protocol
analysis,
first
select
File
>
New
Project
for
a
new
project
or
File
>
Open
to
open
an
existing
protocol
analysis
.gep
file.
(see
“Protocol
Analysis”
on
page 33.
)
You
can
also
open
a
.get
example
file.
Example
files
are
in
the
Examples
folder.
You
can
also
select
File
>
Recent
Projects
to
open
a
project
you
had
recently
saved.
Note:
Select
File
from
the
main
menu
Analyzer
Menu
Bar
or
click
on
the
Hide
Menubar
icon
and
select
File
>
Open.
Clicking
the
Alt
key
toggles
showing/hiding
the
Analyzer
Menu
Bar.
Note:
The
application
prevents
the
host
machine
from
going
into
sleep
mode
to
avoid
loss
of
traces.
The
software
menus
and
toolbar
options
are
explained
in
detail
in
“Software
Menus
and
Toolbar”
on
page 36
.
For
more
information
on
Analyzer
Settings
refer
to
“Analyzer
Settings”
on
page 49.
1.6.1
Easy and Advanced Modes
The
Easy
Mode
provides
the
quickest
way
to
configure
the
analyzer
to
filter
and
trigger
on
events
of
interest.
See
“Trigger
Filter
Settings
in
Easy
Mode”
on
page 64.
Use
Advanced
Mode
only
after
you
become
familiar
with
the
hardware
and
software
and
have
special
needs.
To
start
working
with
the
protocol
analyzer
and
software.
For
more
information
on
Advanced
Mode
refer
to
“Advanced
Mode
(User
‐
Defined)”
on
page 104.
1.6.2
Viewing Captured Data
After
data
capture,
the
captured
data
is
in
the
Viewer,
see
“Display
Manipulation”
on
page 113.
You
can
display
the
same
data
in:
Spreadsheet
View
:
Shows
Protocol
Fields
and
Frames
by
time.
Frame
Inspector
View:
Shows
detail
information
about
packet
highlighted
in
Spreadsheet
or
Packet
views.
Traffic
Summary
View:
The
Traffic
Summary
View
for
each
captured
signal
can
be
viewed.
It
displays
errors
for
the
whole
trace
or
for
a
selected
range.
You
can
show
grid
lines,
select
rows
and
modify
columns.
Data
View:
The
Data
View
displays
information
in
Hexadecimal
and
ASCII
format.
1.6.3
Preferences
For
special
work,
you
can
use
the
Preferences
menu
to
configure
Software
Settings,
Port
Alias,
Address
Alias
and
Display
Settings.
(See
“Preferences”
on
page 149
.)
Summary of Contents for SierraNet M408
Page 1: ...SierraNet M408 User Manual Software Version 1 70 Generated December 15 2014 09 58 ...
Page 8: ...Teledyne LeCroy Contents viii SierraNet M408 User Manual ...
Page 40: ...Teledyne LeCroy CrossSync Control Panel 32 SierraNet M408 User Manual ...
Page 120: ...Teledyne LeCroy Advanced Mode User Defined 112 SierraNet M408 User Manual ...
Page 224: ...Teledyne LeCroy Running Scenarios 216 SierraNet M408 Protocol Analyzer User Manual ...
Page 242: ...Teledyne LeCroy 234 SierraNet M408 User Manual ...
Page 244: ...Teledyne LeCroy 236 SierraNet M408User Manual ...