SierraNet
M408
User
Manual
103
Trigger
Filter
Settings
in
Easy
Mode
Teledyne
LeCroy
Figure 2.81: Pre-Trigger Example, 20% Pre-Trigger
Buffer Size and Segments
The
Analyzer
Settings
panel
has
the
Recording
Buffer
pane
where
you
can
set
Number
of
Segments
and
the
Segment
Size.
The
defaults
are
one
segment
of
25MB.
The
total
size
used
is
automatically
displayed
for
you.
Setting
multiple
segments
will
allow
to
trigger
on
the
first
occurrence
of
the
trigger
condition,
fill
up
the
first
segment,
then
automatically
re
‐
arm
the
trigger
and
repeat
the
remaining
number
of
segments
specified.
You
can
use
the
slider
button
or
click
the
up
or
down
arrow
to
change
memory
usage
for
recording
trace
data.
(Minimum
size
of
memory
is
1MB.
Maximum
size
of
memory
is
dependent
on
the
hardware.)
(See
Figure 2.36
on
page 59
.)
Enter
an
integer
Num.
of
Segment
,
from
1
to
32,
then
enter
an
integer
Segment
Size
in
kilobytes,
up
to
the
memory
size
in
megabytes
divided
by
the
number
of
segments.
The
default
1.
The
New
Project
dialog
opens
with
default
settings
to
capture
Everything
on
the
bus
and
to
Trigger
On
on
Snapshot.
(The
analyzer
captures
everything
immediately
without
triggering
on
anything
in
particular.)
Each
time
a
trigger
condition
occurs,
the
system
records
a
new
segment.
You
can
use
a
Snapshot
or
Pattern
trigger,
but
not
Manual
Trigger.
As
the
same
trigger
automatically
repeats,
the
system
makes
the
number
of
segments
that
you
entered.
Note:
If
the
size
of
a
data
packet
exceeds
the
buffer
memory
allocation,
the
project
runs,
but
no
data
capture
occurs.
You
must
increase
buffer
memory
size
to
a
value
greater
than
the
packet
size.
Trigger Position
You
can
set
the
trigger
position
in
the
captured
buffer
as
a
percentage
of
the
segment
size.
Trigger
point
of
0%
means
the
trigger
point
will
be
on
the
first
packet
in
the
buffer.
To
upload
segments
automatically
for
display
as
the
system
creates
them,
do
not
select
the
checkbox.This
defaults
to
1,
which
defines
the
amount
of
data
to
capture
before
and
after
the
triggering
Event.
You
can
change
this
percentage
by
dragging
the
slider.
In
certain
cases,
when
one
port
is
recording
traffic
and
filling
up
the
memory
much
faster
than
another
port,
you
might
see
traffic
appearing
only
on
one
port
for
a
while,
and
the
Summary of Contents for SierraNet M408
Page 1: ...SierraNet M408 User Manual Software Version 1 70 Generated December 15 2014 09 58 ...
Page 8: ...Teledyne LeCroy Contents viii SierraNet M408 User Manual ...
Page 40: ...Teledyne LeCroy CrossSync Control Panel 32 SierraNet M408 User Manual ...
Page 120: ...Teledyne LeCroy Advanced Mode User Defined 112 SierraNet M408 User Manual ...
Page 224: ...Teledyne LeCroy Running Scenarios 216 SierraNet M408 Protocol Analyzer User Manual ...
Page 242: ...Teledyne LeCroy 234 SierraNet M408 User Manual ...
Page 244: ...Teledyne LeCroy 236 SierraNet M408User Manual ...