SierraNet
M408
User
Manual
5
Analyzer
Overview
Teledyne
LeCroy
1.1.5
Status and Configuration Display
The
Analyzer
front
LCD
display
indicates
the
configuration
and
status
of
the
device.
For
example,
during
initialization,
the
LCD
panel
displays
boot
status
messages.
1.1.6
LCD Display and Button Functions for Configuring the Analyzer
The
basic
settings
of
the
SierraNet
M408
can
be
configured
from
the
unit
itself.
Five
buttons
are
provided
to
enable
you
to
configure
the
Analyzer.
When
you
first
turn
on
the
Analyzer,
after
initialization,
the
LCD
displays
SierraNet
M408
Available
with
two
arrows
pointing
up
and
down
as
shown
in
the
illustration
below.
Figure 1.5: LCD Display and Button on the Front Panel
When
connected
via
ethernet
or
USB,
the
Up
and
Down
buttons
display
the
following:
Displays
current
Static
or
Dynamic
IP
Address
SierraNet
M408
SN
(serial
number)
Connection
Unit
Name
Set
IP
Configuration
IP
Mode
Dynamic,
or
IP
Mode
Static
The
Left
and
Right
buttons
are
used
to
change
the
configuration
properties.
The
LCD
will
display
Button
Inactive
In
This
MenuItem
if
the
button
does
not
serve
any
purpose
for
that
selection.
Perform
the
following
steps
to
set
IP
Configuration,
Static
on
Dynamic
IP
using
the
buttons
and
the
LCD
display
on
the
Analyzer:
Set IP Configuration
To
set
IP
Configuration:
1. Press
the
Up
Button
once
to
get
into
the
Set
IP
Configuration
mode.
2. Press
the
Center
Button
once
to
select
Set
IP
Configuration
.
SierraNet M408
Available
Up
Button
Down
Button
Left
Button
Right
Button
LCD
Display
Center
Button
Summary of Contents for SierraNet M408
Page 1: ...SierraNet M408 User Manual Software Version 1 70 Generated December 15 2014 09 58 ...
Page 8: ...Teledyne LeCroy Contents viii SierraNet M408 User Manual ...
Page 40: ...Teledyne LeCroy CrossSync Control Panel 32 SierraNet M408 User Manual ...
Page 120: ...Teledyne LeCroy Advanced Mode User Defined 112 SierraNet M408 User Manual ...
Page 224: ...Teledyne LeCroy Running Scenarios 216 SierraNet M408 Protocol Analyzer User Manual ...
Page 242: ...Teledyne LeCroy 234 SierraNet M408 User Manual ...
Page 244: ...Teledyne LeCroy 236 SierraNet M408User Manual ...