3700 Portable Samplers
Section 3 Programming Guidelines
3-42
Sampling Retries –
The Sampling Retries option is available
when the detector is enabled. It sets the number of times (from 0
to 3) the sampler will try to detect liquid in the line before
skipping the sample. You can use this option when sampling
liquid with a high concentration of solids that tend to clog the
suction line or the strainer. The sampler will also retry the rinse
cycle when you are using the Sampling Retry option. (
Display
#243
)
3.9.6 Programming Mode
The Programming Mode option allows you to specify either basic
or extended programming mode. The basic programming mode is
used for conventional routines; you can use the extended pro-
gramming mode for either conventional or more complex rou-
tines. Storm programming is available through the extended
programming mode.
Table
3-3 summarizes the sampling features according to the
programming mode in the program sequence. Table
3-1 summa-
rizes the features available in the configure sequence. (
Display
#250
)
Table 3-3 Sampling Capabilities Through the Program Sequence
Pacing
Mode
Feature
Time-Pacing:
Uniform Time Intervals
Basic & Extended
Samples taken at regular time intervals from 1 minute to 99 hours,
59 minutes.
Time-Pacing:
Nonuniform Clock Time
Intervals
Extended
Samples taken at irregular time intervals by specifying the time
and date of each sample. You can enter dates as far as one
month in advance of the current date.
Time-Pacing:
Nonuniform Intervals in
Minutes
Extended
Samples taken at irregular time intervals by specifying the amount
of time in minutes between each sample. You can enter intervals
from 1 to 999 minutes.
Flow-Pacing
Basic & Extended
Samples taken at regular flow intervals. The sampler will totalize
flow intervals of 1 to 9,999 pulses.
Distribution
Sequential
Basic & Extended
One sample volume placed in each bottle.
Samples-per-Bottle
Multiplexing
Basic & Extended
More than one sample volume placed in each bottle. You can
switch bottles after a specified number of samples have been
deposited or after a specified time period.
Bottles-per-Sample
Multiplexing
Basic & Extended
Sample volumes placed in more than one bottle at each sample
event.
Multiple-Bottle
Compositing
Extended
More than one sample volume placed in a set of bottles. You can
switch bottle sets after a specified number of samples have been
deposited or after a specified time period.
Volumes and Accuracy
Sample Volume
Basic & Extended
You can enter volumes from 10 to 9,990 ml.
Suction Head
Basic & Extended
You can enter suction heads from 1 to 20 feet.
Summary of Contents for 3700
Page 2: ......
Page 4: ......
Page 33: ...3700 Portable Samplers Section 2 Setup Procedures 2 9 Figure 2 7 Locked Sampler ...
Page 34: ...3700 Portable Samplers Section 2 Setup Procedures 2 10 ...
Page 144: ...3700 Portable Samplers Section 3 Programming Guidelines 3 110 ...
Page 152: ...3700 Portable Samplers Section 4 Options and Interfacing Equipment 4 8 ...
Page 164: ...3700 Portable Samplers Section 5 Routine Maintenance 5 12 ...
Page 180: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 2 ...
Page 181: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 3 ...
Page 182: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 4 ...
Page 183: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 5 ...
Page 184: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 6 60 3703 262 REV J 3 2 ...
Page 186: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 8 ...
Page 188: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 10 ...
Page 189: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 11 ...
Page 190: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 12 ...
Page 191: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 13 ...
Page 192: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 14 ...
Page 193: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 15 ...
Page 194: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 16 ...
Page 195: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 17 ...
Page 196: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 18 ...
Page 200: ...3700 Portable Samplers Appendix B Accessories B 4 ...
Page 210: ...3700 Portable Samplers Appendix C General Safety Procedures C 10 ...
Page 224: ...3700 Portable Samplers Appendix E Calculating Flow Increment Between Samples E 4 ...
Page 234: ...3700 Portable Samplers Appendix G Material Safety Data Sheets G 8 ...
Page 238: ......
Page 240: ......
Page 242: ......