3700 Portable Samplers
Section 3 Programming Guidelines
3-105
Power –
The sample event was initiated to compensate for a
missed sample which should have occurred while the sampler
was without power. If more than one sample was missed, only
one sample will be taken.
Enable –
The sample event was initiated when the sampler
became enabled by a device connected to pin F of the flow meter
connector, generally a 4200 Series Flow Meter, a 4100 Series
Flow Logger, or Liquid Level Actuator. This source is also
reported when the sample was initiated at a programmed
resume time. Two different configure option settings control this
event: the Sample Upon Enable setting in the Enable Pin con-
figure option and the Sample at Resume setting in the Sampling
Stop/Resume configure option.
Manual –
The sample event was initiated with the manual
sample key and was counted as one of the programmed sample
events.
Time Switch –
The sample event was initiated at the pro-
grammed switch time. This event is controlled by the Sample at
Time Switch setting in the Flow Mode Sampling configure
option. This option is available for flow-paced sampling only.
Disable –
The sample event was initiated when the sampler
became disabled by a device connected to pin F of the flow meter
connector, generally a 4200 Series Flow Meter, a 4100 Series
Flow Logger, or a Liquid Level Actuator. This source is also
reported when the sample was taken at a programmed stop time.
Two different configure option settings control this event: the
Sample Upon Disable setting in the Enable Pin configure option
and the Sample at Stop setting in the
Sampling Stop/Resume
configure option.
3.17.5 Error Messages and
Missed Samples
The probable cause of any missed sample is reported after the
sample number/source display. A missed sample display is illus-
trated below.
Twelve causes are tracked and reported:
Pump ’
STOP
’ Key Hit! –
The sampler was halted with the stop
key during the sample event.
Pump Jammed! –
The sampler was unable to take the sample
because the pump jammed.
Started Too Late! –
The sampling routine was started after the
programmed start time for the first sample. This message is
reported for all samples skipped because of an expired start time.
Program Halted! –
The sampling routine was interrupted by
the
STOP
or
EXIT
PROGRAM
key when the sample event was to occur.
Power Lost! –
The sampler was unable to take the sample
because the sampler’s power source was disconnected.
SAMPLE MISSED:
NO LIQUID DETECTED!
Summary of Contents for 3700
Page 2: ......
Page 4: ......
Page 33: ...3700 Portable Samplers Section 2 Setup Procedures 2 9 Figure 2 7 Locked Sampler ...
Page 34: ...3700 Portable Samplers Section 2 Setup Procedures 2 10 ...
Page 144: ...3700 Portable Samplers Section 3 Programming Guidelines 3 110 ...
Page 152: ...3700 Portable Samplers Section 4 Options and Interfacing Equipment 4 8 ...
Page 164: ...3700 Portable Samplers Section 5 Routine Maintenance 5 12 ...
Page 180: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 2 ...
Page 181: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 3 ...
Page 182: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 4 ...
Page 183: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 5 ...
Page 184: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 6 60 3703 262 REV J 3 2 ...
Page 186: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 8 ...
Page 188: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 10 ...
Page 189: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 11 ...
Page 190: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 12 ...
Page 191: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 13 ...
Page 192: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 14 ...
Page 193: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 15 ...
Page 194: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 16 ...
Page 195: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 17 ...
Page 196: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 18 ...
Page 200: ...3700 Portable Samplers Appendix B Accessories B 4 ...
Page 210: ...3700 Portable Samplers Appendix C General Safety Procedures C 10 ...
Page 224: ...3700 Portable Samplers Appendix E Calculating Flow Increment Between Samples E 4 ...
Page 234: ...3700 Portable Samplers Appendix G Material Safety Data Sheets G 8 ...
Page 238: ......
Page 240: ......
Page 242: ......