3700 Portable Samplers
Section 3 Programming Guidelines
3-24
5.
To verify the Bottles and Sizes settings, press the
ENTER
/
PROGRAM
key. The display shown in Step
5
will appear.
SELECT OPTION: (
← →
)
BOTTLES AND SIZES
6.
Select “PORTABLE” or “REFRIG” depending upon which model you have. Enter PORTABLE for either the 3700
Standard or Compact.
{
PORTABLE
, REFRIG
SAMPLER
7.
For the purposes of this example, select “24” when you are using the 24-bottle base. Use the arrow keys until “24”
blinks, then press the
ENTER
/
PROGRAM
key. Select “1” when you are using a single-bottle for composite sampling.
{1, 4, 12,
24
}
BOTTLES
8.
Enter the bottle size here. Enter “350” for the 350 ml glass bottles, “1000” for plastic bottles, for example. Press
the
ENTER
/
PROGRAM
key. If you enter a number that exceeds the maximum standard bottle size (15,000), the
message, “WARNING: STANDARD BTL VOLUME EXCEEDED!,” will display for a short time. The sampler will
then prompt you to confirm the volume entered. This prompt is displayed in Step 9.
BOTTLE VOLUME IS
1000
ml
9.
Select “YES” if you want to use the nonstandard bottle volume. Select “NO” if you want to revise the entry. The
display shown in step 8 will reappear; use it to enter the revised bottle volume. Press the
ENTER
/
PROGRAM
key to
accept the entry and advance to step 10
1001 ml! . . . ARE YOU
SURE? {YES,
NO
}
10. Press the
ENTER
/
PROGRAM
key at this display to access the Suction-Line input displays shown in steps 11 to 13.
SELECT OPTION: (
← →
)
SUCTION LINE
11. Select “
1
/
4
” if you are using
1
/
4
-inch suction line, “
3
/
8
” if you are using
3
/
8
-inch suction line. Press the
ENTER
/
PROGRAM
key to accept the selection. If you select “
1
/
4
,” you will not see the display shown in step
12
;
instead you will be prompted for the suction-line length, as shown in step
13.
(You do not need to specify vinyl line
type because only
1
/
4
-inch suction line is available.)
SUCTION LINE ID IS
{ 1/4,
3/8
} INCH
12. This display appears when you have selected “
3
/
8
” in step
11
. Select “VINYL” if you are using vinyl suction line,
“TEFLON” if you are using TEFLON suction line. Press the
ENTER
/
PROGRAM
key to accept the selection
SUCTION LINE IS
{
VINYL
, TEFLON}
13. Enter the length of the suction line. Do not include the tube coupling or the strainer in the length. Press the
ENTER
/
PROGRAM
key to accept the entry and move to step
14
. If you change the suction line settings, the “. . .
CALCULATING . . . PUMP TABLE VALUES” message will appear for a short time
SUCTION LINE LENGTH
IS 10 FEET (3 - 99)
14. Press the
ENTER
/
PROGRAM
key at this display to access the Liquid Detector input displays shown in steps 15 to
18.
SELECT OPTION: (
← →
)
LIQUID DETECTOR
Example: Checking the Configure Option Settings (Continued)
Summary of Contents for 3700
Page 2: ......
Page 4: ......
Page 33: ...3700 Portable Samplers Section 2 Setup Procedures 2 9 Figure 2 7 Locked Sampler ...
Page 34: ...3700 Portable Samplers Section 2 Setup Procedures 2 10 ...
Page 144: ...3700 Portable Samplers Section 3 Programming Guidelines 3 110 ...
Page 152: ...3700 Portable Samplers Section 4 Options and Interfacing Equipment 4 8 ...
Page 164: ...3700 Portable Samplers Section 5 Routine Maintenance 5 12 ...
Page 180: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 2 ...
Page 181: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 3 ...
Page 182: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 4 ...
Page 183: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 5 ...
Page 184: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 6 60 3703 262 REV J 3 2 ...
Page 186: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 8 ...
Page 188: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 10 ...
Page 189: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 11 ...
Page 190: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 12 ...
Page 191: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 13 ...
Page 192: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 14 ...
Page 193: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 15 ...
Page 194: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 16 ...
Page 195: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 17 ...
Page 196: ...3700 Portable Samplers Appendix A Replacement Parts Lists A 18 ...
Page 200: ...3700 Portable Samplers Appendix B Accessories B 4 ...
Page 210: ...3700 Portable Samplers Appendix C General Safety Procedures C 10 ...
Page 224: ...3700 Portable Samplers Appendix E Calculating Flow Increment Between Samples E 4 ...
Page 234: ...3700 Portable Samplers Appendix G Material Safety Data Sheets G 8 ...
Page 238: ......
Page 240: ......
Page 242: ......