Performance Tests
1- 38
RSA3408A Technical Reference
2.
Check residual response in the baseband:
a.
Measure residual response:
H
Press the
LINES
key on the front panel.
H
Press the
Show Line
side key to select
Vertical
.
H
Press the
Number Of Line
key to select
1
.
H
With the
Line1
side key, set the value to 1 MHz using the numeric
keypad.
H
Press the
Show Line
side key to select
Horizontal
.
H
Press the
Number Of Line
key to select
1
.
H
With the
Line1
side key, set the value to --93 dBm using the numeric
keypad.
b.
Check against limits:
Confirm that the residual signal level is --93 dBm or less at 1 MHz or
more.
3.
Check residual response in the RF1 band:
a.
Modify the analyzer controls:
H
Press the
FREQUENCY/CHANNEL
key on the front panel.
H
With the
Center Freq
side key, set the frequency to 2 GHz using the
numeric keypad.
H
Press the
SPAN
key on the front panel.
H
With the
Span
side key, set the span to 3 GHz using the numeric
keypad.
b.
Measure residual response:
H
Press the
LINES
key
H
Press the
Show Line
side key to select
Horizontal
.
H
Press the
Number Of Line
key to select
1
.
H
Press the
Line1
side key and set the value to --90 dBm using the
numeric keypad.
c.
Check against limits:
Confirm that the residual signal level is --90 dBm or less.