Performance Tests
1- 32
RSA3408A Technical Reference
c.
Set the signal generator (Item 2) controls:
Frequency
1999.85 MHz
. . . . . . . . . . . . . . . .
Level
0 dBm
. . . . . . . . . . . . . . . . . . . .
ALC BW
100 Hz
. . . . . . . . . . . . . . . .
d.
Set the signal generator (Item 3) controls:
Frequency
2000.15 MHz
. . . . . . . . . . . . . . . .
Level
0 dBm
. . . . . . . . . . . . . . . . . . . .
ALC BW
100 Hz
. . . . . . . . . . . . . . . .
e.
Initialize the analyzer:
H
Press the
SYSTEM
key on the front panel.
H
Press the
Reset All to Factory Defaults
side key.
f.
Modify the default controls:
H
Press the
FREQUENCY/CHANNEL
key on the front panel.
H
The
Center Freq
menu item is selected by default.
Set the frequency to 2 GHz using the numeric keypad.
H
Press the
SPAN
key on the front panel.
H
The
Span
menu item is selected by default.
Set the span to 1 MHz using the general purpose knob.
H
Press the
AMPLITUDE
key on the front panel.
H
The
Ref Level
menu item is selected by default.
Set the level to 5 dBm using the general purpose knob.
H
Press the
RF Atten/Mixer
side key to select
Rf Att
.
H
Press the
RBW/FFT
key on the front panel.
H
Press the
RBW/FFT
side key to select
Man
.
H
Press the
Extended Resolution
side key to select
On
.
H
Press the
RBW
side key and set the RBW to 2 kHz.
H
Press
TRACE/AVG
>
Trace 1 Type...
>
Average
.
H
Press the
Number Of Averages
side key and set the value to 50
using the general purpose knob.
H
Press the
MARKER SETUP
key.
H
Press the
Markers
side key to select
Delta
.