G10 Installation Guide 7.13.2
50
3
Connect Ethernet and SAS Cabling
Rev. 005-140228
Connect SAS Cabling ( IAP200/IAP320)
SAS cabling connections vary depending on the RTM installed with the IIC200. Refer to
the following sections for your specific configuration:
SRM200 RTM SAS Connections (One or Two Controllers)
TRM100 RTM SAS Connections (One or Two Controllers)
SRM200 RTM SAS Connections (One or Two Controllers)
Use
to connect SAS cables from the G10 to one or two controller enclosures.
For
one controller configurations, connect Controller Enclosure 0.
for
information about cabling expansion enclosures. This configuration uses 1-to-2 SAS
connector cables. The 1-to-2 SAS cables are labeled with “P1” and “P2” on the connector
ends that attach to the enclosures to ensure proper cabling. P1 connectors should always
attach to Module A; P2 connectors should always connect to Module B.
If the G10 is supporting two controller disk arrays, it is recommended that you label
the controller enclosure connections as soon as you begin cabling so they can be
easily identified during deployment and for maintenance. Due to the increased
performance of the SA200R, only one controller enclosure is required for a
deployment using this model.
Tektronix Communications | For Licensed Users | Unauthorized Duplication and Distribution Prohibited