G10 Installation Guide 7.13.2
39
2
Install Hardware and Power Cabling
Rev. 005-140228
DC Units
The DC power cables for the G10 probe need to be attached to the plugs on the back of the
unit.
Connect all cabling on the G10 and storage enclosure before connecting the cables
to the Fuse Panel to minimize risk of electrical hazard.
Step
Action
1.
Set the breakers on the PEM face plates to the OFF (tripped) position if they are
not already in this position.
Make sure that the external power feeds you plan to attach are powered off and
cannot be switched on while you are working.
2.
Remove the insulation from the ends of the power cables by stripping the ends
of the cables 10mm.
3.
Loosen the screws on both sides of the pluggable screw terminals on the rear of
the G10 chassis and remove the pluggable screw terminals (
Figure 2.24 - G10 DC Pluggable Screw Terminals
4.
Insert the crimped ends of the power cables into the rectangular openings
(3.5 mm x 3.5 mm wide) of the pluggable screw terminals. Insert the red wire
into the RTN opening and insert the black wire into the -48V opening
(
).
Figure 2.25 - G10 DC Pluggable Screw Terminals
Red
Wire
Black
Wire
Fasten Screws
(1/8-inch wide
flat blade
screw driver
only)
Tektronix Communications | For Licensed Users | Unauthorized Duplication and Distribution Prohibited