Install Hardware and Power Cabling
Rev. 005-140228
I
NSTALL
S
TORAGE
E
NCLOSURES
If installing several enclosures, refer to
for more information about
positioning several enclosures in a rack. This procedure
Four-Post Rack, Front Mount
The storage enclosures must be securely mounted to the front of the four-post rack (also
known as flush mount). Brackets shipped with the storage enclosure provide labels for
installing in 30-inch, 36-inch, 42-inch, and 1000 MM four-post racks. Please note that these
values reflect general rack/cabinet sizes and do not represent specific distances.
Step
Action
1.
Determine the location in the rack in which you will install the storage enclosure
(see
). Mark the location on the front and back of the
rack posts or note the height measurement of the rack label. This will enable
you to correctly align the front and rear brackets.
For IAP100/PRM100 RTM configurations, make sure to leave 1U of space below the
G10 to allow for SAS cabling from the SAS AMC on the font of the G10 to the back of
the controller enclosure(s).
2.
SA100R, SA100J, SA200R, and SA200J
: Remove the two plastic ear caps
) from each side of the front of the storage enclosure by grasping the
top and bottom of each cap and pulling it straight off the enclosure.
Figure 2.8 - SA100R, SA100J, SA200R, and SA200J Storage Enclosure Ear Caps
Left Ear Cap
Right Ear Cap