G10 Installation Guide 7.13.2
141
C
Rev. 005-140228
Replacing G10 Shelf Managers (SHMMs)
CAUTION: SHMMs must always be replaced in pairs.
Failure to follow these steps can lead to corrupted shelf FRU information (such as
part number and serial number), which can render the probe offline and require
complete chassis replacement. Contact Tektronix Communications Customer
Support for assistance with G10 SHMM replacement.
Replacing the First (Standby) SHMM
DO NOT power off the probe to swap SHMMs. The probe MUST remain powered ON.
A Tektronix Communications Customer Support representative will assist you with the
following steps to remove the SHMM from the G10.
Step
Action
1.
Log in to the
active
SHMM and verify that it is “active” or “running alone.”
2.
Remove the Ethernet cables from the
standby
SHMM.
3.
Unfasten the screws of the faceplate until the handle is detached from the front
panel of the board (
Figure C.36
).
The blue Hot Swap LED starts to blink. WAIT until the blue LED stops blinking
and is solid blue.
Figure C.36 - SHMM Faceplate
4.
Remove the SHMM from the shelf using the extraction handles (
Figure C.36
).
5.
Insert the replacement SHMM into the shelf by placing the left and right edges
of the board in the card guides of the shelf.
6.
Slide the board into the shelf by using the extraction handles until you feel
resistance.
7.
Wait until the blue Hot Swap LED is illuminated.
Hot Swap LED
ACT MGMT
OK
OOS
Ethernet
Management
Connector
Ethernet
Uplink
Connector
Handle
Extraction Handles
Tektronix Communications | For Licensed Users | Unauthorized Duplication and Distribution Prohibited