G10 Installation Guide 7.13.2
137
C
Rev. 005-140228
RTMs
Perform the following to reset or remove an RTM.
Step
Action
1.
Depending on which RTM you are removing, power down the associated
blade first:
SRM200 RTM—Power down the IIC200 first. Refer to
Removing or
Resetting the IIC100 or IIC200
.
Media Probe Configurations Only: If replacing an SRM200 RTM during maintenance,
you must verify the J8 jumper setting is TERMINATED prior to installation (see the
Media Probe Installation Guide for details).
SRM100 RTM—Power down the IIC100 first. Refer to
Removing or
Resetting the IIC100 or IIC200
.
TRM100 RTM—Power down the IIC100 first. Refer to
Removing or
Resetting the IIC100 or IIC200
.
PRM100—Power down the IAP100 first. Refer to
Removing or Resetting
the IAP100
.
PRM200—Power down the IAP200 first. Refer to
Removing or Resetting
the IAP200/IAP320
.
PRM300—Power down the IAP320 first. Refer to
Removing or Resetting
the IAP200/IAP320
.
2.
When the associated blade’s Hot Swap LED is solid blue, its OS has powered
down completely.
3.
Pinch the latch and lever on the RTM right ejector handle and pull the handle
outward slightly. The blue Hot Swap LED starts to blink.
Tektronix Communications | For Licensed Users | Unauthorized Duplication and Distribution Prohibited