Change Password configuration menu (optional)
Use this function to change an existing password used to access the optional security functions. This menu is only shown on
instruments with optional security functions installed.
To access the Change Password configuration menu:
1. Tap Utility in the Menu bar
2. Tap Security.
3. Tap Change Password.
Change Password menu fields and controls
3
.
Field or control
Description
Current Password
Enter the current password in this field.
4
New Password
Enter the new password in this field.
6
Repeat New Password
Re-enter the new password in this field.
6
Delete Password
Deletes the password from the security function. You must enter the correct password before
you can clear it.
If the password is correct, the password is deleted and the menu closes. The Security menu
changes the name of the Delete Password button to Set Password.
If the incorrect password is entered, the instrument shows an error message.
NOTE. Once you delete the password, you must set a new password before you can change
the security access functions.
Set New Password
Sets the new password and closes the menu if the current password is correct, the new
password matches in both new password fields, and the new password fields are not empty.
Any other conditions result in an error message.
Cancel
Closes the menu without taking any action.
Passwords and sending the instrument for service. If you need to send the instrument for service or repair, make sure to use
the Clear Password function before sending to the Tektronix Service Center. Failure to do so may impede servicing the
instrument.
Demo (Utility menu)
Use this menu to access demonstrations of key oscilloscope features.
To open the Demo configuration menu, select Utility > Demo... in the Menu bar.
3
If the instrument has a keyboard attached, and you have disabled the USB ports, double-tap on the password field to open the virtual keyboard and enter the password.
4
The valid range of characters for the password is from one to 32 characters. Entering no characters or more than 32 characters results in an error message.
Menus and dialog boxes
302
MSO54, MSO56, MSO58, MSO58LP, MSO64 Help
Summary of Contents for 6 series
Page 24: ...Product documents and support 4 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 42: ...Options 22 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 54: ...Install your instrument 34 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 84: ...Getting acquainted with your instrument 64 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 102: ...Configure the instrument 82 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 148: ...Advanced triggering 128 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 154: ...Zooming on waveforms 134 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 438: ...Waveform acquisition concepts 418 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 448: ...Waveform display concepts 428 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 518: ...Index 498 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...