Harmonics measurement: Configure panel.
Field or control
Description
Standard
Sets the standard to use for measurements. None (no Standard), IEC 61000-3-2, MIL-
STD-1399, AM14, or D0-160G (Standard for Airborne equipment. Supported for harmonics
measurement for single phase DUT).
Harmonics
Sets the harmonics order (number of harmonics) for the selected standard. Ranges from 40 to
100.
Voltage Source
Selects the voltage source used to take the measurement. Tap the field to show the list of
available sources.
Current Source
Selects the current source used to take the measurement. Tap the field to show the list of
available sources.
Line Frequency
Sets the line frequency of the power signal source.
In Auto mode, the application measures the frequency of the input signal automatically. Input
signal is used to compute harmonics in the current source. Default is Auto.
Label
Sets the name of the measurement. You can use the default name, or double-tap in the field
and change the label using a connected keyboard or the virtual keyboard.
Harmonics Source
Selects the source of harmonics calculation source (Voltage or Current) for computation of the
Harmonics.
Power Level (MIL-STD-1399) Selects the required power level, High or Low. It is used to compute limit values for MIL-
STD-1399.
Current (MIL-STD-1399)
Selects either rated or measured. Specify the value for rated or measure the Input current
signal.
Start Frequency
Specify the fundamental frequency to be measured for each standard.
■
None: The values are Auto, 50, 60, 400, or Custom (specify the start Frequency)
■
IEC-61000-3-2: The values are Auto, 50, 60, or Custom
■
MIL-STD-1399: The values are Auto, 400, or Custom
■
AM-14: The values are Auto, 50, 60, or Custom
■
D0-160G: The values are Auto, 360, 400, 800, or Custom
Default is Auto. The measured frequency value is displayed in the measurement badge.
Power Quality measurement: Configure panel.
Field or control
Description
Voltage Source
Selects the voltage source used to take the measurement. Tap the field to show the list of
available sources.
Current Source
Selects the current source used to take the measurement. Tap the field to show the list of
available sources.
Label
Sets the name of the measurement. You can use the default name, or double-tap in the field
and change the label using a connected keyboard or the virtual keyboard.
Calculate Over Full Cycles
Enables calculating the measurement over the entire acquisition.
Frequency Reference
Selects the signal source (Voltage or Current) to use to determine the measurement frequency.
Menus and dialog boxes
MSO54, MSO56, MSO58, MSO58LP, MSO64 Help
177
Summary of Contents for 6 series
Page 24: ...Product documents and support 4 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 42: ...Options 22 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 54: ...Install your instrument 34 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 84: ...Getting acquainted with your instrument 64 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 102: ...Configure the instrument 82 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 148: ...Advanced triggering 128 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 154: ...Zooming on waveforms 134 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 438: ...Waveform acquisition concepts 418 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 448: ...Waveform display concepts 428 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 518: ...Index 498 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...