Ethernet serial bus trigger settings panel
NOTE. Requires option SRENET.
Field or control
Description
Source
Select the Ethernet bus on which to trigger.
Trigger On
Select the type of information on which to trigger.
MAC Address Destination,
Source
Sets the MAC destination and/or source address pattern on which to trigger.
Tap a Binary or Hex field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = MAC Addresses.
MAC Length/Type
Sets the MAC length/type pattern on which to trigger.
Tap a Binary or Hex field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = MAC Length / Type.
MAC Length/Type Low, MAC
Length/Type High
Sets the boundary MAC length type conditions when testing for in-range or out of range
conditions.
Available when Trigger On = MAC Length / Type and Trigger When = Inside Range or
Outside Range.
IP Protocol
Sets the IP protocol pattern on which to trigger.
Tap a Binary or Hex field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = IP Header.
Source, Destination Address Sets the source and/or destination IP address pattern on which to trigger.
Tap a Hex or Decimal field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = IP Header.
Source Port, Destination
Port
Sets the source and/or destination TCP header port pattern on which to trigger.
Tap a Binary, Hex or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = TCP Header.
Sequence Number
Sets the TCP header sequence number pattern on which to trigger.
Tap a Binary, Hex or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Available when Trigger On = TCP Header.
Menus and dialog boxes
350
MSO54, MSO56, MSO58, MSO58LP, MSO64 Help
Summary of Contents for 6 series
Page 24: ...Product documents and support 4 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 42: ...Options 22 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 54: ...Install your instrument 34 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 84: ...Getting acquainted with your instrument 64 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 102: ...Configure the instrument 82 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 148: ...Advanced triggering 128 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 154: ...Zooming on waveforms 134 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 438: ...Waveform acquisition concepts 418 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 448: ...Waveform display concepts 428 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...
Page 518: ...Index 498 MSO54 MSO56 MSO58 MSO58LP MSO64 Help ...