D-50
7. Use a USB cable to connect the printer to the host computer.
8. Start up the host computer.
9. Turn on the printer. The following message appears in the display.
10. Perform steps 6 through 10 of “Procedure for Upgrading the Firmware” to update the
firmware.
11. Check that the following message appears in the display to indicate that the updating of
the firmware has been completed correctly.
12. Turn off the printer.
13. Change the settings for jumper switches CJ1 and CJ2 on the Controller/Mechanical
Control Board from “2-3” to “1-2”. (Return them to their default settings.)
14. Remove Service Download BIOS U19 and U26 from memory sockets U19 and U26 on
the Controller/Mechanical Control Board.
15. Install the NIC Board. (only when the optional NIC Board is mounted)
16. Install the Rear Cover.
17. Turn on the printer.
4980D053AA
4980D051AB
Field_Service_E.book 50 ページ 2004年2月25日 水曜日 午後6時59分
Summary of Contents for UA1610
Page 1: ...SERVICE MANUAL 2004 3 Ver 2 0 FIELD SERVICE UA1610 UA1610f...
Page 22: ...GENERAL...
Page 34: ...MAINTENANCE...
Page 43: ...DIS REASSEMBLY ADJUSTMENT...
Page 95: ...CONTROL PANEL SERVICE MODE DESCRIPTIONS...
Page 287: ...TROUBLESHOOTING...
Page 331: ...AF 1610 Service Manual...
Page 333: ...ii 1 The Original misfeeds T 7 3 TIMING CHART T 8...
Page 334: ...GENERAL...
Page 336: ...DIS REASSEMBLY ADJUSTMENT...
Page 351: ...TROUBLESHOOTING...
Page 360: ...PF 1610 Service Manual...
Page 362: ...GENERAL...
Page 364: ...DIS REASSEMBLY ADJUSTMENT...
Page 371: ...NC 1610 IFC1610 Service Manual...
Page 373: ...GENERAL...
Page 375: ...DIS REASSEMBLY Updating the Firmware...
Page 380: ...TROUBLESHOOTING...