S-56
(14) E-mail setting 2
• Available only if the Internet Fax & Network Scan Kit SU-6 is installed.
• Depending on the network environment in which the machine is located, there may be
some restrictions on the network functions that the machine can use. Make the network
settings to suit the functions and environment required for customer’s location. The net-
work settings can be specified from the control panel or using the administrator mode of
PageScope Light.
No.
Function
Purpose
Setting Details/Precautions
1
POP3
SERVER
This function is used to enter the
IP address or host name of an
POP3 server.
NOTE
Please consult customer’s net-
work administrator for information
about the IP address to use.
• Up to 64 characters can be
entered for the host name.
• The DNS settings must have
been specified before speci-
fying the host name for the
POP3 server.
2
POP3 PORT
NO.
This function is used to enter the
port number (1 to 65535) for the
POP3 server.
NOTE
Please consult customer’s net-
work administrator for information
about the port number to use.
• The port number can be set
between 1 and 65535.
• Normally, port number 110 is
used.
3
POP3 TIME-
OUT
This function is used to specify the
length of time (in seconds) before
the connection to the POP3 server
times out. (30 to 300 seconds)
• The default setting is “60”.
• The time out period can be
between 30 and 300 sec-
onds.
4
POP3
ACCOUNT
This function is used to enter the
account name used to log on to the
POP3 server.
NOTE
Please consult customer’s net-
work administrator for information
about the account name to use.
Up to 64 characters can be
entered for the account name.
Field_Service_E.book 56 ページ 2004年2月25日 水曜日 午後6時59分
Summary of Contents for UA1610
Page 1: ...SERVICE MANUAL 2004 3 Ver 2 0 FIELD SERVICE UA1610 UA1610f...
Page 22: ...GENERAL...
Page 34: ...MAINTENANCE...
Page 43: ...DIS REASSEMBLY ADJUSTMENT...
Page 95: ...CONTROL PANEL SERVICE MODE DESCRIPTIONS...
Page 287: ...TROUBLESHOOTING...
Page 331: ...AF 1610 Service Manual...
Page 333: ...ii 1 The Original misfeeds T 7 3 TIMING CHART T 8...
Page 334: ...GENERAL...
Page 336: ...DIS REASSEMBLY ADJUSTMENT...
Page 351: ...TROUBLESHOOTING...
Page 360: ...PF 1610 Service Manual...
Page 362: ...GENERAL...
Page 364: ...DIS REASSEMBLY ADJUSTMENT...
Page 371: ...NC 1610 IFC1610 Service Manual...
Page 373: ...GENERAL...
Page 375: ...DIS REASSEMBLY Updating the Firmware...
Page 380: ...TROUBLESHOOTING...