D-12
(6)
Automatic Document Feeder Sub-Scanning Zoom Ratio Adjustment
<Reference>
<Adjustment Procedure>
1. Print the test pattern.
2. Enter the “ADJUST” menu in the Service mode.
3. Load the test pattern into the Automatic Document Feeder and make a test copy.
NOTE
•
The test pattern should be positioned vertically.
•
Use A4 L or Letter L paper loaded into Tray 1 to make the test copy.
4. If the length of C in the copy of the test pattern is not the same as the length of C in the
test pattern, adjust it according to the following procedure.
5. Change the setting.
If the width of C in the test pattern is longer than the specified width . . . . .
Decrease the setting.
If the width of C in the test pattern is shorter than the specified width . . . . .
Increase the setting.
✽
If the shift cannot be adjusted to within the specification with a single adjustment, perform
the adjustment again to change the setting.
6. Press the Yes key to apply the setting.
NOTE
If the Stop key is pressed, instead of the Yes key, the main screen is displayed and the set-
ting returns to that before it was changed.
Load the test pattern into the Automatic Document Feeder again, make another test copy,
and check it.
Zoom Ratio
Specification
Mode
Function
Setting Range
Full Size
(100%)
200 ± 0.5 mm “ADJUST” menu ADF SUB ZOOM
95 to 105
1 increment = 0.4%
• Adjust the length of C in the copy of the test pat-
tern so that the following specification is met.
1382D009AA
C
Field_Service_E.book 12 ページ 2004年2月25日 水曜日 午後6時59分
Summary of Contents for UA1610
Page 1: ...SERVICE MANUAL 2004 3 Ver 2 0 FIELD SERVICE UA1610 UA1610f...
Page 22: ...GENERAL...
Page 34: ...MAINTENANCE...
Page 43: ...DIS REASSEMBLY ADJUSTMENT...
Page 95: ...CONTROL PANEL SERVICE MODE DESCRIPTIONS...
Page 287: ...TROUBLESHOOTING...
Page 331: ...AF 1610 Service Manual...
Page 333: ...ii 1 The Original misfeeds T 7 3 TIMING CHART T 8...
Page 334: ...GENERAL...
Page 336: ...DIS REASSEMBLY ADJUSTMENT...
Page 351: ...TROUBLESHOOTING...
Page 360: ...PF 1610 Service Manual...
Page 362: ...GENERAL...
Page 364: ...DIS REASSEMBLY ADJUSTMENT...
Page 371: ...NC 1610 IFC1610 Service Manual...
Page 373: ...GENERAL...
Page 375: ...DIS REASSEMBLY Updating the Firmware...
Page 380: ...TROUBLESHOOTING...