Outputs
Consistent with DCD 5 MHz outputs
Connector card
4 BNC outputs, each with a right-angle (RA) adapter
NTP Server Card
Network Protocol
NTP v3 – RFC1305 compliant
IPv4
Time Stamping
Hardware Time Stamping
Inputs
Stratum 1:
Time-of-Day feed from TimeSource
Type: Cisco ToD
Connector: RJ-45
Format: RS-422 (1000 ft/302 m range)
Stratum 2:
Full NTP Client with peering
NTP Traffic Ports
2 Ethernet Small Form-factor Pluggable (SPF)
(only one port available at release)
Optical: 1000BaseX
Electrical 100/1000BaseT (1000BaseT available at release)
NTP Transaction Rate1000/s fully authenticated (up to 1500/s unauthenticated,
uniform distribution)
Authentication
MD5 (RFC1321)
Protection
1–1 Protection (only one active at a time)
Management port
Integrated with TimeHub system management; physically
isolated from NTP traffic ports.
Output Alarms
Connector Type:
Wire-wrap pins
Connector Label:
OFFICE ALARMS (NC, C, NO)
Connector Location:Input/Alarm Connector card (rear)
Contact Type:
Dry contact
Severity:
Critical (audible and visible)
Major (audible and visible)
Minor (audible and visible)
State:
Normally open and normally closed