![Symmetricom TimeHub 5500 User Manual Download Page 270](http://html.mh-extra.com/html/symmetricom/timehub-5500/timehub-5500_user-manual_1419592270.webp)
270 TimeHub 5500 User’s Guide
097-55501-01 Revision M – January 2009
Chapter 6 Specifications
Specifications
PRS Reference Input
Connector Type:
BNC
Connector Label:
5/10 MHz IN
Connector Location:Input/Alarm Connector card (rear of shelf)
Number of Inputs:
1
Frequency:
5 MHz or 10 MHz
Impedance:
50
Format:
Sine or square wave
Amplitude:
0.5 V p-p
Composite Clock Inputs
Connector Type:
Wire-wrap pins
Connector Label:
CC IN 1 (T, R, S)
CC IN 2 (T, R, S)
Connector Location:Input/Alarm Connector card (rear of shelf)
Number of Inputs:
2
Bit Rate:
64 kb/s
Impedance:
133
Format:
Bipolar RTZ
DS1 Outputs
Connector Type:
Wire-wrap pins
Connector Label:
1–20 (S, T, R)
Connector Location:Wire-wrap panel
Number of Outputs: Up to 40 protected or non-protected outputs per card
Maximum of 140 per master shelf. Additional capacity
available using Expansion shelves
Bit Rate:
1.544 Mb/s