112 TimeHub 5500 User’s Guide
097-55501-01 Revision M – January 2009
Chapter 3 Installing the TimeHub 5500
Installing Modules into the Rear Panel
Figure 3-12. Location of Output Connector Modules on the Rear Panel of the Expansion Shelf
Installing the NTP Output Connector Module
Symmetricom provides two NTP Output Connector modules for use in the Master
shelf, and one NTP Connector module for use in the Expansion shelf.
Master Shelf
You
must
install the NTP Output Connector module in the output group that
corresponds with the front panel slot in which the NTP Server card is installed.
When you install the NTP Server card in any slot from A1 to C6, install the
double-wide NTP Output Connector module (part number 090-55594-01) in the
corresponding group (A, B, or C) on the rear panel of the Master shelf, or
Install a single-wide NTP Output Connector module (part number
090-55594-03) on ports 1–20 of groups A, B, or C. Leave ports 21–40 blank.
When you install the NTP Server card in slot D7 or D8, install the single-wide
NTP Output Connector module (part number 090-55594-03) in Group D on the
rear panel of the Master shelf.
1. Align the pins on the rear of the module with the connector on the shelf
2. Carefully seat the module onto the shelf.
3. Tighten the captive screws located at the top and bottom of the module.