![Symmetricom TimeHub 5500 User Manual Download Page 128](http://html.mh-extra.com/html/symmetricom/timehub-5500/timehub-5500_user-manual_1419592128.webp)
128 TimeHub 5500 User’s Guide
097-55501-01 Revision M – January 2009
Chapter 3 Installing the TimeHub 5500
Installing Expansion Shelves
Installing Output Connector Modules
You can install up to 16 Output Connector panels in any of the locations on the rear
panel of an Expansion shelf, as shown in
. The Output Connector
module determines the type of output signal generated. Each Output Connector
module provides connections for 20 signals from the Output Driver cards. The
Output Connector modules for an Expansion shelf cannot be used on a
Master/Remote shelf.
For DS1 outputs, use connector module part number 090-55591-02, which is part of
the DS1 Output Module Kit (990-55591-02).
Figure 3-22. Location of Output Connector Modules on the Rear Panel of the Master/Remote Shelf
For CC outputs, use connector module part number 090-55593-02, which is part of
the CC Output Module Kit (990-55591-02).
To install the Output Connector module on an Expansion shelf, align the pins on the
rear of the module with the connector on the shelf. The vertical connector should be
facing to the left and the small connector should be on the bottom facing towards
the mating connector on the shelf. Carefully seat the module onto the shelf. Tighten
the captive screws to complete the installation.
A 1-20
A 21-40
C 1-20
C 21-40
B 1-20
B 21-40
D 1-20
D 21-40
E 1-20
E 21-40
F 1-20
F 21-40
G 1-20
G 21-40
H 1-20
H 21-40