![Symmetricom TimeHub 5500 User Manual Download Page 213](http://html.mh-extra.com/html/symmetricom/timehub-5500/timehub-5500_user-manual_1419592213.webp)
097-55501-01 Revision M – January 2009
TimeHub 5500 User’s Guide 213
Chapter 5 Maintaining the TimeHub 5500
Troubleshooting the TimeHub 5500
Table 5-1. Troubleshooting the Clock Card Front Using the LEDs
Name
State
Description
Action
Power
Off
Power is not present.
1.
If all LEDs on the shelf are off,
apply power or troubleshoot the
–48 V power source.
2.
If all LEDs on the Clock card are
off, replace the card as described
in
3.
If the Fuse LED is lit, replace the
fuse as described in
4.
If the replacement fuse fails,
replace the card as described in
Green
Power is present.
None required.
Fuse
Off
The Clock card fuse is not
open.
None required.
Red
The Clock card fuse is open.
1.
Replace the fuse as described in
Replacing the Fuse in the Clock
Card
2.
If the replacement fuse fails,
replace the card as described in
Alarm
Off
There is no alarm condition.
None required.
Red
An alarm condition exists.
If the Fail LED is also lit, replace the
card as described in
, on page 238. If the Fail
LED is not lit, check the Clock card
LEDs and other card LEDs, and/or
troubleshoot the error message(s) to
determine the cause of the alarm.
Refer to the
TL1 Reference
for details
on error messages.
Fail
Off
No hardware or firmware
failure has occurred on the
Clock card.
None required.
Red
A hardware or firmware
failure has occurred on the
Clock card.
Replace the card as described in